Please use this identifier to cite or link to this item: http://library.iigm.res.in:8080/xmlui/handle/123456798/300
Title: Harnessing electron spin hyperpolarization in chromophore− radical spin probes for subcellular resolution in Electron Paramagnetic Resonance Imaging: concept and feasibility
Authors: Rane, Vinayak
Keywords: Electron Paramagnetic Resonance Imaging
EPRI
Electron spin hyperpolarization
Issue Date: 2022
Citation: Journal of Physical Chemistry B, Vol. 126, 14, https://doi.org/10.1021/acs.jpcb.1c10920
Abstract: Obtaining a subcellular resolution for biological samples doped with stable radicals at room temperature (RT) is a long-sought goal in electron paramagnetic resonance imaging (EPRI). The spatial resolution in current EPRI methods is constrained either because of low electron spin polarization at RT or the experimental limitations associated with the field gradients and the radical linewidth. Inspired by the recent demonstration of a large electron spin hyperpolarization in chromophore-nitroxyl spin probe molecules, the present work proposes a novel optically hyperpolarized EPR imaging (OH-EPRI) method, which combines the optical method of two-photon confocal microscopy for hyperpolarization generation and the rapid scan (RS) EPR method for signal detection. An important aspect of OH-EPRI is that it is not limited by the abovementioned restrictions of conventional EPRI since the large hyperpolarization in the spin probes overcomes the poor thermal spin polarization at RT, and the use of two-photon optical excitation of the chromophore naturally generates the required spatial resolution, without the need for any magnetic field gradient. Simulations based on time-dependent Bloch equations, which took into account both the RS field modulation and the hyperpolarization generation by optical means, were performed to examine the feasibility of OH-EPRI. The simulation results revealed that a spatial resolution of up to 2 fL can be achieved in OHEPRI at RT under in vitro conditions. Notably, the majority of the requirements for an OH-EPRI experiment can be fulfilled by the currently available technologies, thereby paving the way for its easy implementation. Thus, the proposed method could potentially bridge the sensitivity gap between the optical and magnetic imaging techniques.
URI: http://library.iigm.res.in:8080/xmlui/handle/123456798/300
Appears in Collections:Miscellaneous Publications

Files in This Item:
File Description SizeFormat 
Rane,Vinayak_JournPhysicalChemistry_2022.pdf
  Restricted Access
1.8 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.