Tri-axial square Helmholtz coil system at the Alibag Magnetic Observatory: upgraded to a magnetic sensor calibration facility

Show simple item record

dc.contributor.author Mahavarkar, Prasanna
dc.contributor.author John, Jacob
dc.contributor.author Dhapre, V.Y.
dc.contributor.author Dongre, Varun
dc.contributor.author Labde, Sachin
dc.date.accessioned 2011-06-18T02:52:19Z
dc.date.accessioned 2021-02-12T09:22:16Z
dc.date.available 2011-06-18T02:52:19Z
dc.date.available 2021-02-12T09:22:16Z
dc.date.issued 2018
dc.identifier.citation Geoscientific instrumentation methods and data systems, 7, 143–149, doi: 10.5194/gi-7-143-2018 en_US
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/1217
dc.description.abstract A tri-axial square Helmholtz coil system for the study of palaeomagnetic studies, manufactured by GEOFYZIKA (former Czechoslovakia), was successfully commissioned at the Alibag Magnetic Observatory (IAGA code: ABG) in the year 1985. This system was used for a few years, after which the system encountered technical problems with the control unit. Rectification of the unit could not be undertaken, as the information document related to this system was not available, and as a result the system had been lying in an unused state for a long time, until 2015, when the system was recommissioned and upgraded to a test facility for calibrating the magnetometer sensors. We have upgraded the system with a constant current source and a data-logging unit. Both of these units have been designed and developed in the institute laboratory. Also, re-measurements of the existing system have been made thoroughly. The upgraded system is semi-automatic, enabling non-specialists to operate it after a brief period of instruction. This facility is now widely used at the parent institute and external institutions to calibrate magnetometers and it also serves as a national facility. Here the design of this system with the calibration results for the space-borne fluxgate magnetometers is presented. en_US
dc.language.iso en_US en_US
dc.subject Alibag magnetic observatory en_US
dc.subject Tri-axial square Helmholtz coil system en_US
dc.subject Paleomagnetic studies en_US
dc.subject Fluxgate magnetometer en_US
dc.title Tri-axial square Helmholtz coil system at the Alibag Magnetic Observatory: upgraded to a magnetic sensor calibration facility en_US
dc.type Article en_US