Geoelectric investigation to delineate groundwater potential and recharge zones in Suki river basin, north Maharashtra

Show simple item record

dc.contributor.author Gupta, Gautam
dc.contributor.author Patil, S.N.
dc.contributor.author Padmane, S.T.
dc.contributor.author Erram, Vinit C.
dc.contributor.author Mahajan, S.H.
dc.date.accessioned 2017-10-24T05:35:00Z
dc.date.accessioned 2021-02-12T10:46:00Z
dc.date.available 2017-10-24T05:35:00Z
dc.date.available 2021-02-12T10:46:00Z
dc.date.issued 2015
dc.identifier.citation Journal of Earth System Science, 124, 7, p .1487–1501 en_US
dc.identifier.uri http://localhost:8080/xmlui/handle/123456789/984
dc.description.abstract Suki river basin of Raver sub-division is located towards the northeastern part of Jalgaon district in Maharashtra State. The existing land use pattern of the region clearly shows that more than 60% of the area is utilized for agricultural sector. Groundwater is the major source of irrigation and domestic purposes. To assess the overall water resources development of Raver area for better environment in future, investigation was carried out with the help of geophysical indicators. Vertical electrical sounding studies were conducted at 17 stations in the study area using Wenner configuration. The study was aimed at characterizing the aquifer in the area as well as assessing its potential risk to contaminant seepage in terms of protective capacity of the overburden rock materials using Dar-Zarrouk (D-Z) parameters, viz., the transverse resistance (T), longitudinal conductance (S), transverse resistivity (ρt) and longitudinal resistivity (ρl). These were computed to generate the resistivity regime of freshwater-bearing formations and its movement. The central-western part of the study area reflects very good to good protective capacity rating as can be seen from the high longitudinal conductance values. The low value of the protective capacity in the eastern part is making the aquifer system in the area highly vulnerable to surface contamination. This indicates that the ground water quality may have been deteriorated in the area and borehole water samples should be randomly sampled for contaminant loads based on this analysis. en_US
dc.language.iso en en_US
dc.subject Groundwater en_US
dc.subject Resistivity en_US
dc.subject Dar-Zarrouk parameters en_US
dc.subject Protective aquifer capacity en_US
dc.subject Raver en_US
dc.subject Jalgaon en_US
dc.title Geoelectric investigation to delineate groundwater potential and recharge zones in Suki river basin, north Maharashtra en_US
dc.type Article en_US
dc.identifier.accession 091526


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account